PA66 Zytel® RS3061HSL BK039A DuPont, European Union
30
- Properties:High temperature resistanGlass fiber reinforced
- Usages:electrical equipmentFitness equipment
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO294-4 | 1.2 % | |
ISO294-4 | 1.2 % | ||
Water absorption rate | ISO62 | 3.8 % | |
ISO62 | 1.7 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Burning rate 3 | ISO3795 | <100 mm/min | |
FMVSS flammability | FMVSS302 | B |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO527-2 | 2400 Mpa | |
Tensile stress | ISO527-2 | 68.0 Mpa | |
Tensile strain | ISO527-2 | 4.5 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO179/1eU | 34 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO75-2/B | 140 °C | ||
ISO75-2/A | 50.0 °C | ||
Glass transition temperature 2 | ISO11357-2 | 60.0 °C | |
melting temperature | ISO11357-3 | 223 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.