PA6 6G15ST2 DOMO CHEM GERMANY
37
Form:Granules
Properties:
Filler: Glass fiber reinf15% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler: Glass fiber reinf | 15% filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 40 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 45 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.8mm | UL 94 | HB | |
| Burning rate | FMVSS302 | <100 | mm/min | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ISO 178 | 5200 | Mpa | |
| bending strength | ISO 178 | 200 | Mpa | |
| Tensile strain | Break | ISO 527-2/5 | 3.0 | % |
| tensile strength | Break | ISO 527-2/5 | 130 | Mpa |
| Tensile modulus | ISO 527-2/1 | 6100 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357-3 | 222 | °C | |
| Vicat softening temperature | ISO 306/B50 | 210 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 190 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 215 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD:23°C,72hr | ISO 2577 | 0.40-0.60 | % |
| TD:23°C,72hr | ISO 2577 | 0.80-1.0 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+13 | ohms | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ISO 2039-2 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.