Share
Add to compare

PA6 LUBEMID B27 GF30 FR V0 NATURAL LUBEN PLAST srl

Properties:
Filler glass fiber reinforced material 30% filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler | glass fiber reinforced material | 30% | filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gap23°C3ASTM D25660to70kJ/m²
Impact strength of cantilever beam gap23°C4ASTM D2566.5to7.5kJ/m²
Impact strength of cantilever beam gap23°CISO 180/A6.0to7.0kJ/m²
Suspended wall beam without notch impact strength23°CISO 18060to70kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA6.0to7.0kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU60to70kJ/m²
Impact strength of cantilever beam gap23°C,3.20mmASTM D256A65to75J/m
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant ratingUL 94V-0
Burning wire flammability index2.0mmIEC 60695-2-12960°C
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strengthBreakISO 527-2/1A/5115to125MPa
Tensile strainYieldISO 527-2/1A/51.5to2.0%
Tensile strainBreakISO 527-2/1A/51.5to2.0%
Bending modulusISO 1787200to7700MPa
Tensile modulusISO 527-2/1A/17700to8200MPa
tensile strengthYieldISO 527-2/1A/5115to125MPa
bending strengthISO 178150to160MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,Unannealed,3.20mmASTM D648210to220°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B215to225°C
Hot deformation temperature1.8MPa,Unannealed,3.20mmASTM D648190to200°C
Vicat softening temperature--ISO 306/A120200to210°C
Vicat softening temperature--ISO 306/B120190to200°C
Melting temperatureInternal Method210to225°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 1183/A1.54to1.58g/cm³
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.