PC 9F22110 FR1 4Plas
Properties:
Filler glass fiber reinforced material 10% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 10% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 9.0 | kJ/m² |
| 23°C | ISO 180/1A | 11 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.8mm | UL 94 | V-0 | |
| 1.6mm | UL 94 | V-0 | ||
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 960 | °C |
| Hot filament ignition temperature | 2.0mm | IEC 60695-2-13 | 900 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2/5 | 4000 | MPa |
| tensile strength | Break,23°C | ISO 527-2/5 | 80.0 | MPa |
| Tensile strain | Break,23°C | ISO 527-2/5 | 4.0 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 130 | °C |
| Vicat softening temperature | ISO 306/B | 140 | °C | |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 140 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.29 | g/cm³ | |
| Shrinkage rate | TD | 0.50 | % | |
| MD | 0.50 | % | ||
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.20 | % |
| water content | ISO 960 | <1000 | ppm | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+15 | ohms | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 | ||
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.