PC L-1225L TEIJIN JAPAN
63
Form:Granules | Grade:Injection grade
Properties:
High mobilityFlame retardant
Typical Applications:
Electrical appliancesElectrical fieldElectronic field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical appliances | Electrical field | Electronic field |
| Properties: | High mobility | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ASTM D542 | 1.585 | ||
| transmissivity | 3000μm | ASTM D1003 | 88.0 | % |
| Transmittance rate | ASTM D1003/ISO 13468 | 88 | % | |
| Refractive index | ASTM D542/ISO 489 | 1.585 | ||
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of simply supported beam without notch | ISO 179 | NoBreak | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | 3.0mm | IEC 60695-2-12 | 960 | °C |
| Hot filament ignition temperature | 1.5mm | IEC 60695-2-13 | 875 | °C |
| 3.0mm | IEC 60695-2-13 | 850 | °C | |
| UL flame retardant rating | 1.9mm | UL 94 | HB | |
| 0.40mm | UL 94 | V-2 | ||
| Burning wire flammability index | 1.5mm | IEC 60695-2-12 | 850 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1 | 2400 | Mpa | |
| tensile strength | Yield | ISO 527-2/50 | 61.0 | Mpa |
| Tensile strain | Yield | ISO 527-2/50 | 6.0 | % |
| Nominal tensile fracture strain | ISO 527-2/50 | >50 | % | |
| Bending modulus | ISO 178 | 2350 | Mpa | |
| bending strength | ISO 178 | 93.0 | Mpa | |
| Tensile modulus | ASTM D638/ISO 527 | 2400 | kg/cm²(MPa)[Lb/in²] | |
| elongation | ASTM D638/ISO 527 | 6 | % | |
| Bending modulus | ASTM D790/ISO 178 | 2350 | kg/cm²(MPa)[Lb/in²] | |
| bending strength | ASTM D790/ISO 178 | 93 | kg/cm²(MPa)[Lb/in²] | |
| Elongation at Break | ASTM D638/ISO 527 | >50 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 139 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 126 | °C | |
| Vicat softening temperature | ISO 306/B50 | 146 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 7E-05 | cm/cm/°C |
| TD | ISO 11359-2 | 7E-05 | cm/cm/°C | |
| RTI Elec | 1.5mm | UL 746 | 125 | °C |
| RTI Imp | 1.5mm | UL 746 | 115 | °C |
| RTI Str | 1.5mm | UL 746 | 125 | °C |
| Vicat softening temperature | ASTM D1525/ISO R306 | 146 | ℃(℉) | |
| Linear coefficient of thermal expansion | ASTM D696/ISO 11359 | 0.7 | mm/mm.℃ | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 18.0 | cm3/10min |
| Shrinkage rate | TD:4.00mm | Internal Method | 0.50-0.70 | % |
| MD:4.00mm | Internal Method | 0.50-0.70 | % | |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.20 | % |
| Shrinkage rate | ASTM D955 | 0.5-0.7 | % | |
| Water absorption rate | ASTM D570/ISO 62 | 0.2 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 30 | KV/mm | |
| Relative permittivity | 100Hz | IEC 60250 | 3.10 | |
| 1MHz | IEC 60250 | 3.00 | ||
| Dissipation factor | 100Hz | IEC 60250 | 1E-03 | |
| 1MHz | IEC 60250 | 9E-03 | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 2 | ||
| Surface resistivity | ASTM D257/IEC 60093 | >1×1015 | Ω | |
| Dielectric constant | ASTM D150/IEC 60250 | 3 | ||
| ASTM D150/IEC 60250 | 3.1 | |||
| Arc resistance | ASTM D495/IEC 60112 | 30 | ||
| Volume resistivity | ASTM D257/IEC 60093 | >1×1013 | Ω.cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.