PP SINPOLENE HFR8124 USA Tenor Aps
0
- Usages:Electrical and electronic application fields
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 60 J/m |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Extreme Oxygen Index | ASTM D2863 | 30 % | |
| UL flame retardant rating | UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Bending modulus | ASTM D790 | 2000 MPa | |
| elongation | Break | ASTM D638 | 10 % |
| tensile strength | Ultimate | ASTM D638 | 18.0 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Vicat softening temperature | ASTM D1525 | 155 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 2.5 g/10min |
| density | ASTM D792 | 1.43 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | ASTM D257 | 1.2E+15 ohms·cm | |
| Surface resistivity | ASTM D257 | 1.4E+15 ohms |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shore hardness | ASTM D2240 | 98 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.