PPA GVX-5H EMS-CHEMIE USA
42
Form:Granules | Grade:Enhanced level
Properties:
High temperature resistanThermal stability
Typical Applications:
Electrical fieldElectronic fieldAutomotive interior parts
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Automotive interior parts |
| Properties: | High temperature resistan | Thermal stability |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 80 | kJ/m² |
| -30°C | ISO 179/1eU | 65 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| ISO Type | ISO 1874 | PA66+PA6I/X . MH. 14-190. GF50 | ||
| Flammability level | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2 | 2.5 | % |
| tensile strength | Break | ISO 527-2 | 250 | Mpa |
| Tensile modulus | ISO 527-2 | 18000 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 5.0E-5 | cm/cm/°C |
| Flow | ISO 11359-2 | 2.0E-5 | cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 260 | °C | |
| Continuous use temperature | --4 | Internal Method | 220 | °C |
| --3 | ISO 2578 | 100 to 120 | °C | |
| Hot deformation temperature | 8.0 MPa, Unannealed | ISO 75-2/C | 175 | °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 245 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 1.4 | % |
| Saturation, 23°C | ISO 62 | 4.0 | % | |
| Shrinkage rate | Flow | ISO 294-4 | 0.10 | % |
| 横向Flow | ISO 294-4 | 0.30 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | V | ||
| Dielectric strength | IEC 60243-1 | 33 | KV/mm | |
| Volume resistivity | IEC 60093 | 1.0E+12 | ohms·cm | |
| Surface resistivity | IEC 60093 | -- | ohms | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | ISO 2039-1 | 290 | Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.