Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.41 g/cm³ |
density | | ISO1183 | 1.41 g/cm³ |
Shrinkage rate | | ISO294-4 | 1.1 % |
Shrinkage rate | | ISO294-4 | 0.40 % |
Shrinkage rate | | ISO294-4 | 360 mm |
Ejection Temperature | | | 170 °C |
flammability | Test Condition | Test Method | Test Result |
---|
Burning rate 4 | | ISO3795 | 30 mm/min |
UL flame retardant rating | | UL94 | HB |
UL flame retardant rating | | UL94 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
FMVSS flammability | | FMVSS302 | B |
Fogging-G-value | | ISO6452 | 1E-04 g |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Emissions of Organic Compounds | | VDA277 | 140 µgC/g |
Odor | | VDA270 | 3.00 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-1, -2 | 5700 MPa |
Tensile modulus | | ISO527-2 | 5800 Mpa |
Tensile stress | | ISO527-2 | 109 Mpa |
Tensile strain | | ISO527-2 | 3.5 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO179/1eA | 7.0 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 40 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 5.0 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dissipation Factor | | IEC60250 | 7E-04 |
Dissipation Factor | | IEC60250 | 0.017 |
CTI | | IEC60112 | 225 V |
Surface Resistivity | | IEC60093 | 1E+14 ohms |
Volume resistivity | | IEC60093 | >1.0E+15 ohms·cm |
dielectric strength | | IEC60243-1 | 35 KV/mm |
| | IEC60250 | 3.70 |
| | IEC60250 | 3.60 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | | UL 94 HB |
UL flame retardant rating | | | UL 94 HB |
UL flame retardant rating | | | UL 94 HB |
| | ISO75-2/A | 200 °C |
Melting temperature 5 | | ISO11357-3 | 225 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.