PBT SK602 NC010 DUPONT TAIWAN
40
Form:Granules | Grade:Enhanced level
Properties:
Filler: Glass fiber reinf15% filler by weight15% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler: Glass fiber reinf | 15% filler by weight | 15% filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 7.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 40 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 5.0 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning rate | 1.00mm | ISO 3795 | 30 | mm/min |
| UL flame retardant rating | 1.5mm | UL 94 | HB | |
| 3.0mm | UL 94 | HB | ||
| 1.5mm | IEC 60695-11-10,-20 | HB | ||
| 3.0mm | IEC 60695-11-10,-20 | HB | ||
| FMVSS flammability | FMVSS302 | B | ||
| Fogging-G-value | condensate | ISO 6452 | 1E-04 | g |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 0.00 mm, 23 ℃, Injection Molded | ISO 527-1 | 5700 | MPa |
| ISO 527-2 | 5800 | Mpa | ||
| tensile strength | Break | ISO 527-2 | 109 | Mpa |
| Tensile strain | Break | ISO 527-2 | 3.5 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 6.00 mm | UL 94 | HB | |
| 3.00 mm | UL 94 | HB | ||
| 1.50 mm | UL 94 | HB | ||
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 200 | °C |
| Melting temperature | ISO 11357-3 | 225 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.41 | g/cm³ | |
| ISO 1183 | 1.41 | g/cm³ | ||
| Shrinkage rate | TD | ISO 294-4 | 1.1 | % |
| MD | ISO 294-4 | 0.40 | % | |
| MDLength2(2.00mm) | ISO 294-4 | 360 | mm | |
| Top out temperature | 170 | °C | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 100Hz | IEC 60250 | 7E-04 | |
| 1MHz | IEC 60250 | 0.017 | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 | ||
| Surface resistivity | IEC 60093 | 1E+14 | ohms | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 35 | KV/mm | |
| Relative permittivity | 100Hz | IEC 60250 | 3.70 | |
| 1MHz | IEC 60250 | 3.60 | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| EmissionofOrganicCompounds | VDA277 | 140 | µgC/g | |
| Odor | VDA270 | 3.00 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.