Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | ASTM D1238 | 15 g/10min | |
Flow shrinkage rate | ASTM D955 | 0.50-0.70 % | |
Water absorption rate | ASTM D570 | <0.20 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Fracture tensile strength | ASTM D628 | 63.0 Mpa | |
elongation | 120 | % | |
Flexural modulus | ASTM D790 | 2160 Mpa | |
Impact strength of cantilever beam gap | ASTM D256 | 780 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | ASTM D257 | 1E+16 ohm.cm | |
dielectric strength | ASTM D149 | 20 KV/mm | |
dielectric constant | ASTM D150 | 2.90 | |
arc resistance | ASTM D495 | 110 sec |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ASTM D648 | 132 °C | ||
UL flame retardant rating | UL 94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.