TPU 1185A BASF GERMANY
310
Form:Granules | Grade:Injection grade
Properties:
transparentwear resistantLow temperature resistanc
Typical Applications:
Bottle capAutomotive ApplicationsFitness equipmentCable
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Bottle cap | Automotive Applications | Fitness equipment | Cable |
| Properties: | transparent | wear resistant | Low temperature resistanc |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| characteristic | 用于射出、挤出、吹出 | |||
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| density | DIN 53479 | 1.12 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ASTM D2240/ISO 868 | 36 | Shore D | |
| ASTM D2240/ISO 868 | 87 | Shore A | ||
| tear strength | ASTM D624/ISO 34 | 70 | n/mm² | |
| tensile strength | ASTM D412/ISO 527 | 45 | Mpa/Psi | |
| Tensile modulus | 300% | ASTM D412/ISO 527 | 6 | Mpa/Psi |
| 100% | ASTM D412/ISO 527 | 2.5 | Mpa/Psi | |
| Shore hardness | DIN 53505 | 87 | shoreA | |
| Tensile modulus | 100% | DIN 53504-S2 | 6 | N/mm |
| tensile strength | 80℃水中21天 | DIN 53504-S2 | 32 | N/mm |
| Permanent compression deformation | 70℃ | DIN 53517 | 45 | % |
| Elongation at Break | 80℃水中21天 | DIN 53504-S2 | 600 | % |
| Impact strength of cantilever beam gap | -30℃ | DIN 53453 | 不破裂 | KJ/m |
| Permanent compression deformation | 室温 | DIN 53517 | 25 | % |
| Tensile modulus | 20% | DIN 53504-S2 | 2.5 | N/mm |
| Elongation at Break | DIN 53504-S2 | 600 | % | |
| Shore hardness | DIN 53505 | 36 | Shore D | |
| Impact strength of cantilever beam gap | +23℃ | DIN 53453 | 不破裂 | KJ/m |
| tensile strength | DIN 53504-S2 | 45 | N/mm | |
| tear strength | DIN 53515 | 70 | N/mm | |
| Tensile modulus | 300% | DIN 53504-S2 | 10 | N/mm |
| Friction loss | DIN 53516 | 25 | mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.