Phenolic Resiten® 600

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Water absorption rateASTMD5702.0 %
densityASTMD7921.42 g/cm³
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessASTMD78565
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94HB
Supplementary InformationTest ConditionTest MethodTest Result
BondStrengthASTMD229480000 g
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strengthASTMD638168 MPa
tensile strengthASTMD638114 MPa
bending strengthASTMD790165 MPa
compressive strengthASTMD695153 MPa
compressive strengthASTMD695139 MPa
bending strengthASTMD790203 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTMD25653 J/m
Impact strength of cantilever beam gapASTMD25659 J/m
Electrical performanceTest ConditionTest MethodTest Result
dielectric strengthASTMD14913 kV/mm
dielectric constantASTMD1504.96
Dissipation FactorASTMD1500.051
DielectricBreakdownASTMD149>43000 V
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.