Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| gloss | 60°, 45 m | ASTM D 2457 | 57 - | mm |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Suspended wall beam without notch impact strength | /,23℃ | ISO 179 | 95 | kJ/m² |
| /,-20℃ | ISO 179 | 10 | kJ/m² | |
| Impact strength of cantilever beam gap | /,-40℃ | ISO 179 | 5 | kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | / | ISO 178 | 800 | Mpa |
| tear strength | / | ASTM D 624 | 67 | kN/m |
| Elongation at Break | / | ISO 527-1/-2 | 500 | % |
| elongation | /,Yield | ISO 527-1/-2 | 12 | % |
| tensile strength | /,Break | ISO 527-1/-2 | 30 | Mpa |
| /,Yield | ISO 527-1/-2 | 20 | Mpa | |
| thermal properties | Test Condition | Test Method | Test Result | Test Unit |
| RTI Imp | DSC | UL 746B | 75 | °C |
| Melting temperature | ISO 11357-3 | 163 | °C | |
| Vicat softening temperature | ISO 306/A50 | 145 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | ISO 1133 | 0.9 | g/10min | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | 15 sec | ISO 868 | 57 | D |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.