| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179 | 8.0 | kJ/m² | |
| Impact strength of simply supported beam without notch | ISO 179 | 30 | kJ/m² | |
| Impact strength of cantilever beam gap | ISO 180 | 60 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 650 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2 | 3.5 | % |
| Bending modulus | ISO 178 | 5500 | MPa | |
| Tensile modulus | ISO 527-2 | 6500 | MPa | |
| tensile strength | Break | ISO 527-2 | 115 | MPa |
| bending strength | ISO 178 | 200 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 200 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 190 | °C | |
| Melting temperature | ISO 3146 | 220 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.27 | g/cm³ | |
| Shrinkage rate | 0.40to0.80 | % | ||
| Water absorption rate | Equilibrium,23°C,50%RH | 2.6 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | DIN 53482 | 1E+12 | ohms | |
| Volume resistivity | DIN 53482 | 1E+15 | ohms·cm | |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 0 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | L-Sale | ASTM D785 | 102 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.