PA66 A3GF15 AKRO-PLASTIC GERMANY
103
Form:Granules
Properties:
Glass fiber reinforced
Typical Applications:
Automotive sectorElectronic fieldElectrical field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Electronic field | Electrical field |
| Properties: | Glass fiber reinforced |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 45 | kJ/m² |
| -30°C | ISO 179/1eU | 43 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | 1.6mm | IEC 60695-2-12 | 650 | °C |
| UL flame retardant rating | 0.8mm | UL 94 | HB | |
| Burning rate | 1.00mm | FMVSS302 | <100 | mm/min |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ISO 178 | 6100 | Mpa | |
| bending strength | ISO 178 | 200 | Mpa | |
| Tensile strain | Break | ISO 527-2/5 | 3.5 | % |
| tensile strength | Break | ISO 527-2/5 | 140 | Mpa |
| Tensile modulus | ISO 527-2/1 | 6400 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| TemperatureIndex | 50%LossofTensileStrength,5000hr | IEC 216 | 160to175 | °C |
| 50%LossofTensileStrength,20000hr | IEC 216 | 130to150 | °C | |
| Linear coefficient of thermal expansion | TD:23to80°C | ISO 11359-2 | 1.1E-04 | cm/cm/°C |
| MD:23to80°C | ISO 11359-2 | 3.4E-05 | cm/cm/°C | |
| Melting temperature | DIN EN11357-1 | 262 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 245 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 260 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Hygroscopicity | 70°C,62%RH | ISO 1110 | 2.5to2.7 | % |
| Water absorption rate | Saturation,23°C | ISO 62 | 6.7to7.3 | % |
| Shrinkage rate | MD | ISO 294-4 | 0.40 | % |
| TD | ISO 294-4 | 1.4 | % | |
| Spiral flow length | Internal Method | 99.0 | CM | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+13 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+12 | ohms | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | H961/30 | ISO 2039-1 | 200 | Mpa |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| ReinforcementContent | ISO 1172 | 15 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.