ASA/PC Luran®S S KR2861/1C BK89828 INEOS GERMANY
40
- Properties:High impact resistanceheat-resisting
- Usages:Automotive ApplicationsApplication in the automotive fieldShell
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| bending strength | ISO 178 | 78.0 Mpa | |
| Tensile creep modulus | 1000hr | ISO 899-1 | 1600 Mpa |
| 1hr | ISO 899-1 | 2000 Mpa | |
| Tensile strain | Yield,23°C | ISO 527-2 | 4.9 % |
| tensile strength | Yield,23°C | ISO 527-2 | 53.0 Mpa |
| Tensile modulus | ISO 527-2 | 2300 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Annealed | ISO 75-2/A | 106 °C |
| 0.45MPa,Annealed | ISO 75-2/B | 125 °C | |
| thermal conductivity | DIN 52612 | 0.17 W/m/K | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 7.0E-5到9.0E-5 cm/cm/°C |
| Vicat softening temperature | -- | ISO 306/B50 | 120 °C |
| -- | ISO 306/A50 | 136 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.25 % |
| Saturation,23°C | ISO 62 | 0.90 % | |
| Shrinkage rate | ISO 294-4 | 0.50-0.90 % | |
| Melt Volume Flow Rate (MVR) | 260°C/5.0kg | ISO 1133 | 14.0 cm3/10min |
| 220°C/10.0kg | ISO 1133 | 3.50 cm3/10min |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Dissipation factor | 1MHz | IEC 60250 | 0.015 |
| 100Hz | IEC 60250 | 6E-03 | |
| Dielectric constant | 100Hz | IEC 60250 | 3.40 |
| Volume resistivity | IEC 60093 | 1E+14 ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+13 ohms |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Ball Pressure Test | ISO 2039-1 | 95.0 Mpa |
| film | Test Condition | Test Method | Test Result |
|---|---|---|---|
| elongation | Break | ISO 527-3 | >50 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.