PP Moharamplast PP MP-COAT 9010 Moharamplast S.A.E
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| impact strength | ISO 21809-1 | >100 | J/cm | |
| ISO 21809-1 | >100 | J/cm | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D638 | >21.6 | MPa |
| Yield | ASTM D638 | >21.6 | MPa | |
| Break | ASTM D638 | >29.4 | MPa | |
| elongation | Break | ASTM D638 | >1200 | % |
| tensile strength | Break | ASTM D638 | >29.4 | MPa |
| elongation | Break | ASTM D638 | >1200 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Brittle temperature | ASTM D746 | <-40.0 | °C | |
| Melting temperature | ASTM D2117 | >160 | °C | |
| Brittle temperature | ASTM D746 | <-40.0 | °C | |
| Vicat softening temperature | ASTM D1525 | 140 | °C | |
| ASTM D1525 | 140 | °C | ||
| Melting temperature | ASTM D2117 | >160 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 0.910 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 0.80 | g/10min |
| Environmental stress cracking resistance | -- | ASTM D1693A | >5000 | hr |
| -- | ASTM D1693B | >5000 | hr | |
| -- | ASTM D1693C | >5000 | hr | |
| -- | ASTM D1693C | >5000 | hr | |
| density | ASTM D792 | 0.910 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 0.80 | g/10min |
| Environmental stress cracking resistance | -- | ASTM D1693A | >5000 | hr |
| -- | ASTM D1693B | >5000 | hr | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | ASTM D2240 | >60 | |
| ShoreD | ASTM D2240 | >60 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.