PCTG Tritan™ GN071

553
  • Properties:
    Chemical resistance
    Hydrolysis resistance
  • Usages:
    Electrical applications
    Household daily necessities
  • Certificates:
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.27 g/cm³
Shrinkage rateASTM D9550.20-0.50 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessASTM D785108
optical performance Test ConditionTest MethodTest Result
transmissivityASTM D100390.0 %
Haze ratioASTM D10030.20 %
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapISO 1809.4 kJ/m²
Impact strength of cantilever beam gapASTM D4218NoBreak
Impact strength of cantilever beam gapASTM D4218NoBreak
Impact strength of cantilever beam gapASTM D25640 J/m
Impact strength of cantilever beam gapASTM D256110 J/m
Impact strength of cantilever beam gapISO 1804.4 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile strainISO 527-24.0 %
elongationASTM D638180 %
Tensile strainISO 527-2200 %
Flexural modulusASTM D7902060 Mpa
Flexural modulusISO 1782100 Mpa
bending strengthASTM D79068.0 Mpa
bending strengthISO 17867.0 Mpa
Tensile modulusASTM D6382030 Mpa
Tensile modulusISO 527-22000 Mpa
tensile strength ASTM D63850.0 Mpa
tensile strength ISO 527-248.0 Mpa
tensile strength ASTM D63830.0 Mpa
tensile strength ISO 527-229.0 Mpa
elongationASTM D6384.4 %
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D64870.0 °C
Heat distortion temperatureISO 75-2/B70.0 °C
Heat distortion temperatureASTM D64862.0 °C
Heat distortion temperatureISO 75-2/A62.0 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.