Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 0.060 % |
density | | ISO 1183 | 1.50 g/cm³ |
Shrinkage rate | | ISO 294-4 | 0.55to0.85 % |
Shrinkage rate | | ISO 294-4 | 0.20to0.45 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
UL flame retardant rating | | UL 94 | V-0 |
Burning wire flammability index | | IEC 60695-2-12 | 960 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 875 °C |
UL flame retardant rating | | UL 94 | V-1 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2/1 | 11500 MPa |
Tensile modulus | | ISO 527-2/1 | 11500 MPa |
Tensile modulus | | ISO 527-2/1 | 11000 MPa |
Tensile modulus | | ISO 527-2/1 | 10500 MPa |
Tensile strain | | ISO 527-2/5 | 2.3 % |
Tensile strain | | ISO 527-2/5 | 2.5 % |
Tensile modulus | | ISO 527-2/1 | 10500 MPa |
tensile strength | | ISO 527-2/5 | 175 MPa |
tensile strength | | ISO 527-2/5 | 165 MPa |
tensile strength | | ISO 527-2/5 | 155 MPa |
tensile strength | | ISO 527-2/5 | 135 MPa |
tensile strength | | ISO 527-2/5 | 110 MPa |
Tensile strain | | ISO 527-2/5 | 2.2 % |
Tensile strain | | ISO 527-2/5 | 2.2 % |
Tensile strain | | ISO 527-2/5 | 2.3 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | 10 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 65 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/B | 295 °C |
Heat distortion temperature | | ISO 75-2/A | 290 °C |
Continuous use temperature | | | 230 °C |
vicat | | ISO 306/B50 | >300 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 1.5E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.