PEI 1000R-7101 SABIC INNOVATIVE US
146
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforcedFlame retardantenhance
Typical Applications:
Automotive sectorElectrical fieldElectronic field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Electrical field | Electronic field |
| Properties: | Glass fiber reinforced | Flame retardant | enhance |
Certificates
No Data...
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | Equilibrium,73℉ | ASTM D-570 | 1.25 | % |
| melt mass-flow rate | ASTM D-1238 | 17.8 | g/10min | |
| Water absorption rate | 24hr,73℉ | ASTM D-570 | 0.250 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | ASTM D-256 | 0.6 | ft-lb/in | |
| Yield tensile elongation | ASTM D-638 | 7.0 | % | |
| bending strength | Yield | ASTM D-790 | 22000 | psi |
| Rockwell hardness | ASTM D-785 | 109 | psi | |
| Bending modulus | ASTM D-790 | 480000 | psi | |
| tensile strength | Yield | ASTM D-638 | 15200 | psi |
| Suspended wall beam without notch impact strength | ASTM D-4812 | 25.0 | ft-lb/in | |
| Elongation at Break | ASTM D-638 | 60.0 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | flow | ASTM E-831 | 3 | E-5/in/in℉ |
| Hot deformation temperature | 66Psi | ASTM D-648 | 405 | ℉ |
| 264Psi | ASTM D-648 | 387 | ℉ | |
| Vicat softening temperature | ASTM D-1525 | 426 | ℉ | |
| Combustibility | UL 94 | V-0 | CLASS | |
| Heat index | 非机械性能 | UL 746B | 170 | °C |
| 机械冲击性能 | UL 746B | 170 | °C | |
| 电性能 | UL 746B | 170 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | ASTM D-955 | 5-7 | in/inE-3 | |
| density | ASTM D-792 | 1.27 | ||
| Taber abraser | ASTM D-1044 | 10 | mg/1000次 | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D-257 | 1×10 | Ω.cm | |
| Dielectric strength | 62mils | ASTM D-149 | 830 | v/mil |
| Dielectric constant | 1KHz | ASTM D-150 | 3.15 | |
| Dissipation factor | 1KHz | ASTM D-150 | 0.0013 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.