Share
Add to Compare

PA6 TG7S BASF GERMANY

19

Form:Granules | Grade:Injection grade

Properties:
Glass fiber reinforced
Typical Applications:
Engine parts
Product Description
Certificates(1)
Datasheet

Product Description

Typical Applications:Engine parts
Properties:Glass fiber reinforced

Certificates

UL
UL

Technical Data Sheet

otherTest ConditionTest MethodTest ResultTest Unit
characteristic可加工性良好 良好的流动性 良好的抗撞击性
purpose汽车领域的应用 座椅
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strength-40℉,BreakASTM D63836400psi
tensile strength176℉,BreakASTM D63814100psi
tensile strength248℉,BreakASTM D63811200psi
Tensile stress-40℉,BreakISO 527-136400psi
Tensile stress176℉,BreakISO 527-114100psi
Tensile stress248℉,BreakISO 527-111200psi
Fracture stressISO 527-125000psi
Elongation at Break-40℉ASTM D6383.9%
Elongation at Break176℉ASTM D6386.7%
Elongation at Break248℉ASTM D6387.0%
Fracture strainISO 527-13.3%
Bending modulus73℉ASTM D7901.3E+06psi
Bending modulus73℉ISO 1781.22E+06psi
bending strength73℉ASTM D79037700psi
Charpy Notched Impact Strength23℃ISO 179/1eA10.9ft·lb/in
Impact strength of cantilever beam gap-40℉ISO 1808.57ft·lb/in
Impact strength of cantilever beam gap73℉ISO 18012.4ft·lb/in
tensile strengthBreak,150°CISO 527-266.0Mpa
Tensile strainBreak,-40°CISO 527-23.9%
Tensile strainBreak,23°CISO 527-23.3%
Tensile strainBreak,80°CISO 527-26.7%
Tensile strainBreak,120°CISO 527-27.0%
Tensile strainBreak,150°CISO 527-27.1%
Bending modulus23°CISO 1788400Mpa
tensile strengthBreak,-40°CISO 527-2251Mpa
tensile strengthBreak,23°CISO 527-2170Mpa
tensile strengthBreak,80°CISO 527-297.0Mpa
tensile strengthBreak,120°CISO 527-277.0Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Melting temperature428
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A203°C
Melting temperatureISO 3146220°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.