physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.16 g/cm³ | |
spiral flow length | 86.4 cm | ||
Shrinkage rate | ASTM D955 | 0.40to0.50 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-1 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
elongation | Break | ASTM D638 | 20 % |
Flexural modulus | ASTM D790 | 2340 MPa | |
bending strength | ASTM D790 | 70.3 MPa | |
Tensile modulus | ASTM D638 | 2340 MPa | |
tensile strength | Yield | ASTM D638 | 39.3 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256A | 370 J/m |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Elec | UL 746 | 80.0 °C | |
Heat distortion temperature | ASTM D648 | 82.8 °C | |
ASTM D648 | 88.9 °C | ||
ASTM D648 | 77.2 °C | ||
ASTM D648 | 86.1 °C | ||
ASTM D648 | 91 °C | ||
RTI Imp | UL 746 | 70.0 °C | |
RTI | UL 746 | 80.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.