PA6 Comco PA6G MO Comco Nylon GmbH
Typical Applications:
pulley
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | pulley |
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | 3.0mm | UL 94 | HB | |
| 6.0mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 4000 | MPa | |
| tensile strength | Yield | ISO 527-2 | 80.0 | MPa |
| Tensile strain | Break | ISO 527-2 | >20 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357 | 220 | °C | |
| Linear coefficient of thermal expansion | MD:20to55°C | ISO 11359-2 | 8E-05 | cm/cm/°C |
| thermal conductivity | DIN 52612 | 0.26 | W/m/K | |
| Usage temperature | LongTerm | -40-100 | °C | |
| ShortTerm | -100-170 | °C | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.15 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+12 | ohms | |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 25 | kV/mm | |
| Dielectric constant | 50Hz | IEC 60250 | 4.00 | |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 0 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | DIN 53505 | 84 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.