physical property | Test Condition | Test Method | Test Result |
---|
Melt volume flow rate | | ISO 1133 | 14 cm3/10min |
Water absorption rate | | ISO 62-2 | 1.2 % |
Water absorption rate | | ISO 62-2 | 0.5 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ISO 527-2 2 | 3 Mpa |
Tensile strain | | ISO 527-2 2 | > 50 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA 2 | -- |
Charpy Notched Impact Strength | | ISO 179/1eA 2 | -- |
Charpy Notched Impact Strength | | ISO 179/1eU 2 | -- |
Charpy Notched Impact Strength | | ISO 179/1eU 2 | -- |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | ISO 1210 2 | HB |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 2 | -- ohms |
Volume resistivity | | IEC 60093 2 | 1300000000000 ohms·cm |
dielectric strength | | IEC 60243-1 2 | 36 KV/mm |
relative permittivity | | IEC 60250 2 | 6 |
relative permittivity | | IEC 60250 2 | 6 |
Dissipation Factor | | IEC 60250 2 | 0.055 |
Dissipation Factor | | IEC 60250 2 | 0.038 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 2 | |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2 2 | 42 °C |
melting temperature | | ISO 11357-3 2 | 134 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 2 | 0.00020 1/℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.