plas
Log In

HDPE Halene H P5200 HALDIA INDIA

0
  • Usages:
    Pipeline system
  • Compare

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gap23°C,Compression MoldedASTM D256A180 J/m
mechanical propertiesTest ConditionTest MethodTest Result
tensile strengthYield,Compression MoldedASTM D63825.0 MPa
tensile strengthBreak,Compression MoldedASTM D63838.0 MPa
elongationYield,Compression MoldedASTM D6387.0 %
elongationBreak,Compression MoldedASTM D638650 %
Bending modulusCompression MoldedASTM D790A1000 MPa
thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature0.45MPa,UnannealedASTM D64867.0 °C
Vicat softening temperatureASTM D15253121 °C
Oxygen induction timeASTM D3895>30 min
Physical propertiesTest ConditionTest MethodTest Result
densityASTM D7920.948 g/cm³
melt mass-flow rate190°C/5.0kgASTM D12380.80 g/10min
Environmental stress cracking resistance10%Igepal,Compression Molded,F50ASTM D1693B>1000 hr
hardnessTest ConditionTest MethodTest Result
Shore hardnessShoreD,Compression MoldedASTM D224065
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.