Share
Add to compare

TPU 9380A COVESTRO GERMANY

60

Form:Granules | Grade:Injection grade

Properties:
Hydrolysis resistanceAntimicrobialFlexibility at low temper
Typical Applications:
Cable sheathpipeline
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Cable sheath | pipeline
Properties:Hydrolysis resistance | Antimicrobial | Flexibility at low temper

Certificates

No Data...

Technical Data Sheet

elastomerTest ConditionTest MethodTest ResultTest Unit
tear strength23°CISO 34-150kN/m
Permanent compression deformation23°C, 72 hrISO 81525%
Permanent compression deformation70°C, 24 hr5ISO 81537%
Permanent compression deformation70°C, 24 hr7ISO 81525%
ResilienceISO 466250%
squeeze outTest ConditionTest MethodTest ResultTest Unit
drying temperature< 80°C
Melt Temperature195 to 215°C
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strengthBreak, 23°CDIN 5350439.9Mpa
tensile strength10% Strain, 23°CDIN 535041.40Mpa
tensile strength50% Strain, 23°CDIN 535043.90Mpa
tensile strength100% Strain, 23°CDIN 535045.20Mpa
tensile strength300% Strain, 23°CDIN 535049.40Mpa
Tensile strainBreak, 23°CDIN 53504590%
Tensile storage modulus-20°CISO 672173.0Mpa
Tensile storage modulus20°CISO 672137.0Mpa
Tensile storage modulus60°CISO 672130.0Mpa
Wear resistanceISO 464920.0mm³
injectionTest ConditionTest MethodTest ResultTest Unit
drying temperature< 80°C
Processing (melt) temperature205 to 225°C
Mold temperature20 to 40°C
hardnessTest ConditionTest MethodTest ResultTest Unit
Shore hardnessShore A, 1 Sec, 23°CISO 761980
Shore hardnessShore D, 1 Sec, 23°CISO 761931
Shore hardnessShore A, 3 secISO 868380
Shore hardnessShore D, 15 secISO 868331
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.