Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Density (23 ° C) | | g/cm³ | 1.13 -- |
vertical | | % | 1 -- |
flow | | % | 1.1 -- |
Water absorption rate | | % | 9.0 到 10 -- |
Humidity Absorption - 62% RH? | | % | 2.6 到 3.4 -- |
flammability | Test Condition | Test Method | Test Result |
---|
burning rate | | mm/min | < 100 -- |
UL flame retardant rating | | | V-2 -- |
Burning wire flammability index | | °C | 750 -- |
| | °C | 675 -- |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | MPa | 3600 1200 |
Tensile stress (yield) | | MPa | 85 45 |
| | MPa | 3100 -- |
Bending stress 1 | | MPa | 120 -- |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | | 无断裂 -- |
Impact strength of simply supported beam without notch | | | 无断裂 无断裂 |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ohms | 1000000000000 10000000000 |
Volume resistivity | | ohms·cm | 10000000000000 10000000000 |
| | V | 600 -- |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Thermal deformation temperature under load | | °C | 180 -- |
Thermal deformation temperature under load | | °C | 60 -- |
Melting temperature 2 | | °C | 220 -- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.