Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ASTM D955 | 1.3to1.8 % | |
ISO 294-4 | 1.3to1.8 % | ||
Water absorption rate | ASTM D570 | 0.080 % | |
ISO 62 | 0.080 % | ||
density | ASTM D792 | 1.36 g/cm³ | |
ISO 1183 | 1.36 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D638 | 46.0 MPa | |
ISO 527-2/5 | 46.0 MPa | ||
elongation | ASTM D638 | 19 % | |
Break | ISO 527-2/5 | 20 % | |
Flexural modulus | ASTM D790 | 1750 MPa | |
bending strength | ASTM D790 | 58.0 MPa | |
ISO 178 | 60.0 MPa | ||
Flexural modulus | ISO 178 | 1800 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256 | 64 J/m | |
ISO 180/1A | 6.0 kJ/m² |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.