Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Bending modulus | 23°C | ISO 178 | 3900 | Mpa |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 3.7 | kJ/m² |
| -30°C | ISO 179/1eA | 3.4 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 78 | kJ/m² |
| -30°C | ISO 179/1eU | 75 | kJ/m² | |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 6.0 | kJ/m² |
| tensile strength | Yield,23°C | ISO 527-2 | 83 | Mpa |
| Elongation at Break | 23°C | ISO 527-2 | 4.0 | % |
| Tensile modulus | 泊松比 | ISO 527-2 | 0.40 | |
| bending strength | 23°C | ISO 178 | 104 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 240 | °C |
| 1.80MPaAnnealed | ISO 75-2/Af | 75 | °C | |
| 熔点 | ISO 11359-2 | 265 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD2.0mm | ISO 294-4 | 0.90 | % |
| TD2.0mm | ISO 294-4 | 0.60 | % | |
| Water absorption rate | (23°C,24hr) | ISO 62 | 0.80 | % |
| (23°C,50RH) | ISO 62 | 2.3 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 1.0mm | IEC 60243-1 | 17 | KV/mm |
| Dissipation factor | 耐电弧性 | IEC 61621 | 120-179 | S |
| 相对漏电起痕指数 | IEC 60112 | 600 | V | |
| Volume resistivity | IEC 60093 | 1E+10 | Ω.cm | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | V-0 | 0.71mm | |
| UL -94 | V-0 | 1.50mm | ||
| UL -94 | V-0 | 3.00mm | ||
| Extreme Oxygen Index | ISO 4589-2 | 24 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.