physical property Test ConditionTest MethodTest Result
densityISO 1183/B1.20 g/cm³
melt mass-flow rateISO 113310 g/10min
Shrinkage rateISO 294-40.50to0.70 %
optical performance Test ConditionTest MethodTest Result
transmissivityASTM D100387.0to91.0 %
flammabilityTest ConditionTest MethodTest Result
GWITIEC 60695-2-13800 °C
GWITIEC 60695-2-13800 °C
Limiting Oxygen Index (LOI)ISO 4589-240 %
UL flame retardant ratingIEC 60695-2-2PASS
UL flame retardant ratingUL 94V-2
UL flame retardant ratingUL 94V-2
UL flame retardant ratingUL 94V-0
UL flame retardant ratingUL 94V-0
Burning wire flammability indexIEC 60695-2-12960 °C
Burning wire flammability indexIEC 60695-2-12960 °C
Burning wire flammability indexIEC 60695-2-12960 °C
GWITIEC 60695-2-13800 °C
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-2/12400 MPa
tensile strength YieldISO 527-2/5060.0 MPa
tensile strength BreakISO 527-2/5058.0 MPa
Tensile strainYieldISO 527-2/506.0 %
Tensile strainBreakISO 527-2/50>100 %
Flexural modulusISO 1782350 MPa
bending strengthISO 17895.0 MPa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA35 kJ/m²
Impact strength of cantilever beam gapISO 180/A70 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC 60093>1.0E+15 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric strengthIEC 60243-117 kV/mm
Dissipation FactorIEC 602501E-03
Dissipation FactorIEC 602501E-03
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 3
dielectric constantIEC 602502.70
dielectric constantIEC 602502.70
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/A125 °C
Heat distortion temperatureISO 75-2/A141 °C
vicatISO 306/B50143 °C
Ball pressure temperatureIEC 60335-1>130 °C
Linear coefficient of thermal expansionISO 11359-27E-05 cm/cm/°C
Heat distortion temperatureISO 75-2/B144 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.