Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.35 g/cm³ |
density | | ASTM D792 | 1.36 g/cm³ |
Water absorption rate | | ASTM D570 | 5.4 % |
Water absorption rate | | ASTM D570 | 2.5 % |
Water absorption rate | | ASTM D570 | 1.7 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
compressive strength | | ASTM D695 | 44.8 MPa |
compressive strength | | ASTM D695 | >310 MPa |
compressive strength | | ASTM D695 | 130 MPa |
bending strength | | ASTM D790 | 145 MPa |
bending strength | | ASTM D790 | 129 MPa |
bending strength | | ASTM D790 | 161 MPa |
bending strength | | ASTM D790 | 150 MPa |
bending strength | | ASTM D790 | 141 MPa |
bending strength | | ASTM D790 | 137 MPa |
compressive strength | | ASTM D695 | 7.58 MPa |
compressive strength | | ASTM D695 | 6.89 MPa |
compressive strength | | ASTM D695 | >310 MPa |
compressive strength | | ASTM D695 | 117 MPa |
compressive strength | | ASTM D695 | >310 MPa |
tensile strength | | ASTM D638 | 51.7 MPa |
tensile strength | | ASTM D638 | 51.7 MPa |
tensile strength | | ASTM D638 | 85.5 MPa |
tensile strength | | ASTM D638 | 86.2 MPa |
tensile strength | | ASTM D638 | 79.3 MPa |
tensile strength | | ASTM D638 | 86.2 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 81 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 73 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 70 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 84 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 97 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 87 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dissipation Factor | | ASTM D150 | 0.60 |
Dissipation Factor | | ASTM D150 | 0.40 |
Dissipation Factor | | ASTM D150 | 0.31 |
arc resistance | | ASTM D495 | 35.0 sec |
arc resistance | | ASTM D495 | 37.0 sec |
arc resistance | | ASTM D495 | 15.0 sec |
dielectric strength | | ASTM D149 | 22000 V |
dielectric strength | | ASTM D149 | 23000 V |
dielectric strength | | ASTM D149 | 9000 V |
dielectric strength | | ASTM D149 | 6.7 kV/mm |
dielectric strength | | ASTM D149 | 4.6 kV/mm |
dielectric strength | | ASTM D149 | 3.5 kV/mm |
dielectric constant | | ASTM D150 | 21.6 |
dielectric constant | | ASTM D150 | 11.8 |
dielectric constant | | ASTM D150 | 5.57 |
dielectric constant | | ASTM D150 | 23.4 |
dielectric constant | | ASTM D150 | 11.7 |
dielectric constant | | ASTM D150 | 5.60 |
dielectric constant | | ASTM D150 | 32.0 |
dielectric constant | | ASTM D150 | 14.1 |
dielectric constant | | ASTM D150 | 6.47 |
Dissipation Factor | | ASTM D150 | 0.28 |
Dissipation Factor | | ASTM D150 | 0.29 |
Dissipation Factor | | ASTM D150 | 0.099 |
Dissipation Factor | | ASTM D150 | 0.39 |
Dissipation Factor | | ASTM D150 | 0.32 |
Dissipation Factor | | ASTM D150 | 0.082 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.