Share
Add to Compare

PC 503R GY5A716 SABIC INNOVATIVE NANSHA

44

Form:Granules | Grade:Injection grade

Properties:
High mobilityThermal stability
Typical Applications:
Electrical applicationsFitness equipment
Product Description
Certificates(1)
Datasheet

Product Description

Typical Applications:Electrical applications | Fitness equipment
Properties:High mobility | Thermal stability

Certificates

UL
UL

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gapASTM D1822158kJ/m²
Dart impact23°CASTM D3029102J
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating1.5mmUL 94V-0
UL flame retardant rating3.0mmUL 945VA
Extreme Oxygen IndexASTM D286336%
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strengthYieldASTM D63866.2Mpa
tensile strengthBreakASTM D63855.2Mpa
elongationYieldASTM D6388.0%
Taber abraser1000Cycles,1000g,CS-17WheelASTM D104411.0mg
bending strengthYield,50.0mmSpanASTM D790103Mpa
Bending modulus50.0mmSpanASTM D7903450Mpa
elongationBreakASTM D63815%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Linear coefficient of thermal expansionMD:-40to95°CASTME8313.2E-05cm/cm/°C
specific heatASTMC3511210J/kg/°C
thermal conductivityASTMC1770.20W/m/K
RTI ElecUL 746120°C
RTI ImpUL 746110°C
RTI StrUL 746125°C
Hot deformation temperature0.45MPa,Unannealed,6.40mmASTM D648146°C
Hot deformation temperature1.8MPa,Unannealed,6.40mmASTM D648142°C
Vicat softening temperatureASTM D15255154°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateMD:3.20mmInternal Method0.20-0.40%
Water absorption rate24hrASTM D5700.12%
Water absorption rateEquilibrium,23°CASTM D5700.31%
Outdoor applicabilityUL 746Cf1
Specific volumeASTM D7920.802cm³/g
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Volume resistivityASTM D257>1.0E+17ohms·cm
Dielectric strength3.20mm,inAirASTM D14918KV/mm
Dielectric constant50HzASTM D1503.10
Dielectric constant60HzASTM D1503.10
Dielectric constant1MHzASTM D1503.05
Dissipation factor50HzASTM D1508E-04
Dissipation factor60HzASTM D1508E-04
Dissipation factor1MHzASTM D1507.5E-03
Arc resistanceASTM D495PLC7
Hot wire ignitionHWIUL 746PLC 1
High voltage arc tracing rateHVTRUL 746PLC 3
High arc combustion indexHAIUL 746PLC 1
Compared to the anti leakage trace indexCTIUL 746PLC 4
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessR-SaleASTM D785124
Rockwell hardnessM-SaleASTM D78585
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.