PC 503R GY5A716 SABIC INNOVATIVE NANSHA
44
Form:Granules | Grade:Injection grade
Properties:
High mobilityThermal stability
Typical Applications:
Electrical applicationsFitness equipment
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electrical applications | Fitness equipment |
| Properties: | High mobility | Thermal stability |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D1822 | 158 | kJ/m² | |
| Dart impact | 23°C | ASTM D3029 | 102 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5mm | UL 94 | V-0 | |
| 3.0mm | UL 94 | 5VA | ||
| Extreme Oxygen Index | ASTM D2863 | 36 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D638 | 66.2 | Mpa |
| Break | ASTM D638 | 55.2 | Mpa | |
| elongation | Yield | ASTM D638 | 8.0 | % |
| Taber abraser | 1000Cycles,1000g,CS-17Wheel | ASTM D1044 | 11.0 | mg |
| bending strength | Yield,50.0mmSpan | ASTM D790 | 103 | Mpa |
| Bending modulus | 50.0mmSpan | ASTM D790 | 3450 | Mpa |
| elongation | Break | ASTM D638 | 15 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD:-40to95°C | ASTME831 | 3.2E-05 | cm/cm/°C |
| specific heat | ASTMC351 | 1210 | J/kg/°C | |
| thermal conductivity | ASTMC177 | 0.20 | W/m/K | |
| RTI Elec | UL 746 | 120 | °C | |
| RTI Imp | UL 746 | 110 | °C | |
| RTI Str | UL 746 | 125 | °C | |
| Hot deformation temperature | 0.45MPa,Unannealed,6.40mm | ASTM D648 | 146 | °C |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 142 | °C | |
| Vicat softening temperature | ASTM D15255 | 154 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.20-0.40 | % |
| Water absorption rate | 24hr | ASTM D570 | 0.12 | % |
| Equilibrium,23°C | ASTM D570 | 0.31 | % | |
| Outdoor applicability | UL 746C | f1 | ||
| Specific volume | ASTM D792 | 0.802 | cm³/g | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | >1.0E+17 | ohms·cm | |
| Dielectric strength | 3.20mm,inAir | ASTM D149 | 18 | KV/mm |
| Dielectric constant | 50Hz | ASTM D150 | 3.10 | |
| 60Hz | ASTM D150 | 3.10 | ||
| 1MHz | ASTM D150 | 3.05 | ||
| Dissipation factor | 50Hz | ASTM D150 | 8E-04 | |
| 60Hz | ASTM D150 | 8E-04 | ||
| 1MHz | ASTM D150 | 7.5E-03 | ||
| Arc resistance | ASTM D495 | PLC7 | ||
| Hot wire ignition | HWI | UL 746 | PLC 1 | |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 3 | |
| High arc combustion index | HAI | UL 746 | PLC 1 | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 4 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Sale | ASTM D785 | 124 | |
| M-Sale | ASTM D785 | 85 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.