PC/ABS T88GF20-901510 COVESTRO SHANGHAI
159
Form:Granules | Grade:Injection grade
Properties:
heat-resistingFlame retardantFiller: Glass fiber reinf20%Filler by weight20%Filler by weight
Typical Applications:
Automotive ApplicationsElectrical applicationshousehold electrical appliances
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Automotive Applications | Electrical applications | household electrical appliances |
| Properties: | heat-resisting | Flame retardant | Filler: Glass fiber reinf | 20% | Filler by weight | 20% | Filler by weight |
Certificates

Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| tensile strength | 23°C | ISO 527-2 | 120 | Mpa |
| Elongation at Break | 23°C | ISO 527-2 | 2.40 | % |
| Tensile modulus | 23°C | ISO 527-2 | 7200 | Mpa |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 8.00 | kJ/m² |
| -30°C | ISO 180/1A | 8.00 | kJ/m² | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 129 | °C |
| 1.80MPaAnnealed | ISO 75-2/Af | 119 | °C | |
| Vicat softening temperature | ISO 306/B50 | 128 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 3E-05 | cm/cm/°C |
| TD | ISO 11359-2 | 6.5E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.29 | g/cm³ | |
| Shrinkage rate | MD2.0mm | ISO 294-4 | 0.40 | % |
| TD2.0mm | ISO 294-4 | 0.30 | % | |
| Water absorption rate | (23°C,24hr) | ISO 62 | 0.40 | % |
| (23°C,50RH) | ISO 62 | 0.20 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 相对漏电起痕指数 | IEC 60112 | 150 | V |
| 23°C | IEC 60250 | 8.5E-03 | 1MHz | |
| Dielectric constant | 23°C | IEC 60250 | 3.20 | 1MHz |
| Dielectric strength | IEC 60243-1 | 35 | KV/mm | |
| Surface resistivity | IEC 60093 | 1E+17 | Ω.cm | |
| Volume resistivity | IEC 60093 | 1E+16 | Ω.cm | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 0.85mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.