PBT+PET TechnoDur PBT/PET GF 15 Natural (9972) TECHNOCOMPOUND GERMANY

0

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notch23°CISO 179/1eU35 kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU35 kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA6.0 kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA6.0 kJ/m²
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating0.8mmInternal MethodHB
Burning wire flammability index2.0mmIEC 60695-2-12750 °C
mechanical propertiesTest ConditionTest MethodTest Result
Bending strainISO 1784.5 %
bending strength3.5%StrainISO 178160 MPa
bending strength--ISO 178155 MPa
Bending modulusISO 1785000 MPa
tensile strengthBreakISO 527-2/5110 MPa
Tensile modulusISO 527-2/16100 MPa
Tensile strainBreakISO 527-2/53.0 %
thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A190 °C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B210 °C
Linear coefficient of thermal expansionMD:23to80°CISO 11359-23E-05 cm/cm/°C
Melting temperatureISO 11357-3220to255 °C
Vicat softening temperatureISO 306/B50200 °C
Hot deformation temperature8.0MPa,UnannealedISO 75-2/C65.0 °C
Linear coefficient of thermal expansionTD:23to80°CISO 11359-28E-05 cm/cm/°C
Physical propertiesTest ConditionTest MethodTest Result
Water absorption rateSaturation,23°CISO 620.40 %
Water absorption rate23°C,24hrISO 620.20 %
Shrinkage rateMDISO 25770.35 %
Shrinkage rateTDISO 25771.2 %
Melt Volume Flow Rate (MVR)265°C/2.16kgISO 113320.0 cm³/10min
densityISO 11831.43 g/cm³
Electrical performanceTest ConditionTest MethodTest Result
Relative permittivity1MHzIEC 602503.60
Surface resistivityIEC 600931E+15 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
Dielectric strength1.00mmIEC 60243-126 kV/mm
Relative permittivity100HzIEC 602503.80
Compared to the anti leakage trace indexSolutionAIEC 60112PLC 2
hardnessTest ConditionTest MethodTest Result
Ball Pressure TestISO 2039-1190 MPa
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.