plas
Log In

PS Resirene READ 9500 RAF RESIRENE MEXICO

0
  • Usages:
    Electrical and electronic application fields
  • Compare

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gap3.18mmASTM D256120 J/m
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating1.5mmUL 94V-0
mechanical propertiesTest ConditionTest MethodTest Result
elongationBreakASTM D63835 %
elongationYieldASTM D6381.0 %
tensile strengthBreakASTM D63810.0 MPa
tensile strengthYieldASTM D63814.0 MPa
Tensile modulusASTM D6381790 MPa
Physical propertiesTest ConditionTest MethodTest Result
Shrinkage rateMDASTM D9550.40 %
melt mass-flow rate200°C/5.0kgASTM D123810 g/10min
density1.15 g/cm³
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.