PA6 1013G10 MITSUBISHI ENGINEERING JAPAN
124
Form:Granules | Grade:Injection grade
Properties:
heat-resistingAging resistanceFiber optic reinforcementHeat aging
Typical Applications:
Electronic and Electrical Applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic and Electrical Applications |
| Properties: | heat-resisting | Aging resistance | Fiber optic reinforcement | Heat aging |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ISO 179 | 32(127) | KJ/m | |
| elongation | Break | 2.3(12.5) | % | |
| Fracture stress | 100(60) | Mpa | ||
| Bending modulus | D178 | 4500(2200) | Mpa | |
| bending strength | D178 | 172(87) | Mpa | |
| Tensile modulus | ISO 527-1 | 5000(2200) | Mpa | |
| Hot deformation temperature | HDT | D648 | 189(215) | °C |
| Impact strength of cantilever beam gap | ISO 179 | 4(12) | KJ/m | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 1.3 | TD% | ||
| 0.4 | MD% | |||
| Water absorption rate | D570 | 3.1 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the Leakage Traceability Index (CTI) | IEC 112 | 375 | ||
| Dielectric loss | IEC 250 | 0.012(0.022) | ||
| Dielectric constant | ASTM D 790 | 4 | Pf/m | |
| Dielectric strength | IEC 243-1 | 25 | MV/m |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.