PC/ABS GP-5300 LG GUANGZHOU
65
Form:Granules | Grade:Chemical resistance
Properties:
fillingFill reinforcement level
Typical Applications:
Electrical applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical applications |
| Properties: | filling | Fill reinforcement level |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Induced positive connection | ASTM D-150 | 0.008 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | Notched | ASTM D-256 | 14 | kg.cm/cm |
| Rockwell hardness | ASTM D-785 | 83 | M(R) | |
| elongation | ASTM D-638 | 4 | % | |
| ASTM D-638 | 25 | % | ||
| bending strength | ASTM D-790 | 1500 | kg/cm | |
| Impact strength of cantilever beam gap | Notched | ASTM D-256 | 12 | kg.cm/cm |
| Rockwell hardness | ASTM D-785 | 77 | ||
| tensile strength | ASTM D-638 | 950 | kg/cm | |
| Bending modulus | ASTM D-790 | 84000 | kg/cm | |
| ASTM D-790 | 50000 | kg/cm | ||
| tensile strength | ASTM D-638 | 1250 | kg/cm | |
| bending strength | ASTM D-790 | 1850 | kg/cm | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | HB | |||
| Thermal refraction temperature | ASTM D-648 | 125 | °C | |
| ASTM D-648 | 115 | °C | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 2.5-3.5 | cm/cm×0.0001 | ||
| 2-3.5 | cm/cm×0.0001 | |||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Induced positive connection | ASTM D-150 | 0.0085 | ||
| Arc resistance | ASTM D-495 | 123 | sec | |
| Dielectric constant | ASTM D-150 | 3.0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.