Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | | 0.1 % |
UL flame retardant rating | | IEC 60695 | HB |
UL flame retardant rating | | IEC 60695 | V-2 |
Shrinkage rate | | ISO 1874-2 | 1.1 % |
Basic performance | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.17 g/cm |
Water absorption rate | | ISO 62 | 0.6 % |
Water absorption rate | | ISO 62 | 1.2 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eU | 95C KJ/m |
Charpy Notched Impact Strength | | ISO 179/1eA | 16C KJ/m |
fracture strain | | ISO 527-1/2 | 6 % |
Tensile modulus | | ISO 527-1/2 | 5000 MPa |
Charpy Notched Impact Strength | | ISO 179/1eU | 90C KJ/m |
Breaking stress | | ISO 527-1/2 | 105 MPa |
Charpy Notched Impact Strength | | ISO 179/1eA | 25C KJ/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | IEC 60250 | 3.4 |
Comparative Tracking Index | | IEC 60112 | >600 |
electrolytic corrosion | | IEC 60426 | A1 Step |
Dissipation Factor | | IEC 60250 | 260 10 |
Dissipation Factor | | IEC 60250 | 370 10 |
dielectric constant | | IEC 60243-1 | 41 kv/mm |
dielectric constant | | IEC 60250 | 4.1 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 0 |
Volume resistivity | | IEC 60093 | 10 Ω.cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
vicat | | ISO 306 | 175 ℃ |
Melt Temperature | | ISO 3146 | 178 ℃ |
Linear coefficient of thermal expansion | | ISO 11359 | 0.7 10 |
Heat distortion temperature | | ISO 75 | 175 ℃ |
Heat distortion temperature | | ISO 75 | 160 ℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.