physical property Test ConditionTest MethodTest Result
densityISO 11831.47 g/cm³
melt mass-flow rateISO 113318 g/10min
Shrinkage rateDIN 169010.10to0.40 %
Mechanical propertiesTest ConditionTest MethodTest Result
bending strengthISO 178215 MPa
Bending StrainISO 1782.3 %
Tensile strainYieldISO 527-21.8 %
Flexural modulusISO 17811000 MPa
Tensile modulusISO 527-213000 MPa
tensile strength BreakISO 527-2145 MPa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA6.0 kJ/m²
Impact strength of simply supported beam without notchISO 179/1fU26 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
insulation resistanceIEC 60167<1.0E+6 ohms
Thermal performanceTest ConditionTest MethodTest Result
vicatISO 306/A280 °C
Continuous use temperatureUL 746B220 °C
maximum service temperature250 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.