PAEK LUVOCOM® 2205-7123 VP LEHVOSS Group
0
- Properties:Filler carbon fiber reinforced material
- Usages:Medical and nursing supplies
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1fU | 26 kJ/m² |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 6.0 kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| tensile strength | Break | ISO 527-2 | 145 MPa |
| Tensile modulus | ISO 527-2 | 13000 MPa | |
| Bending modulus | ISO 178 | 11000 MPa | |
| Tensile strain | Yield | ISO 527-2 | 1.8 % |
| Bending strain | ISO 178 | 2.3 % | |
| bending strength | ISO 178 | 215 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Maximum operating temperature | ShortTerm | 250 °C | |
| Continuous use temperature | UL 746B | 220 °C | |
| Vicat softening temperature | ISO 306/A | 280 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | DIN 16901 | 0.10to0.40 % | |
| melt mass-flow rate | 380°C/10.0kg | ISO 1133 | 18 g/10min |
| density | ISO 1183 | 1.47 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| insulation resistance | IEC 60167 | <1.0E+6 ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.