PPS DIC.PPS CZL-2000 DIC Corporation
0
- Properties:Filler carbon PTFE
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Suspended wall beam without notch impact strength | ASTM D256 | 200 J/m | |
| Impact strength of cantilever beam gap | ASTM D256 | 45 J/m |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 0.8mm | UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Bending modulus | ASTM D790 | 8000 MPa | |
| elongation | Break | ASTM D638 | 0.80 % |
| compressive strength | ASTM D695 | 120 MPa | |
| bending strength | ASTM D790 | 110 MPa | |
| tensile strength | ASTM D638 | 100 MPa | |
| Tensile modulus | ASTM D638 | 8500 MPa | |
| Friction coefficient | Steel - Static | ASTM D1894 | 0.21 |
| Steel - Dynamic | ASTM D1894 | 0.21 | |
| Poisson's ratio | 0.36 |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Linear coefficient of thermal expansion | TD:-30to90°C | ASTM D696 | 2.1E-05 cm/cm/°C |
| MD:-30to90°C | ASTM D696 | 2.1E-05 cm/cm/°C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 265 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | MD | ASTM D955 | 0.25 % |
| density | ASTM D792 | 1.52 g/cm³ | |
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.070 % |
| Shrinkage rate | TD | ASTM D955 | 0.25 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | ASTM D257 | 1.0E+7到1.0E+8 ohms·cm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | R-Scale | ASTM D785 | 118 |
| M-Scale | ASTM D785 | 98 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.