impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notchISO 17944kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.75 mmUL 94V-0
Burning wire flammability index3.0 mmIEC 60695-2-12960°C
Extreme Oxygen IndexASTM D286338%
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulus23°CISO 527-27500Mpa
tensile strengthBreak, 23°CISO 527-2131Mpa
tensile strength--ASTM D638132Mpa
elongationBreakASTM D6382.5%
elongationBreak, 23°CISO 527-22.5%
Bending modulus--ASTM D7906400Mpa
Bending modulus23°CISO 1787500Mpa
bending strength--ASTM D790191Mpa
bending strength23°CISO 178188Mpa
Taber abraser1000 CyclesASTM D1044--mg
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45 MPa, UnannealedASTM D648255°C
Hot deformation temperature0.45 MPa, UnannealedISO 75-2/B256°C
Hot deformation temperature1.8 MPa, UnannealedASTM D648248°C
Hot deformation temperature1.8 MPa, UnannealedISO 75-2/A240°C
Linear coefficient of thermal expansionFlowASTM D6963.0E-5cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rate横向FlowInternal Method1.0%
Shrinkage rateFlowInternal Method0.60%
Water absorption rateSaturation, 23°C--%
Water absorption rateEquilibrium, 23°C, 50% RHISO 62--%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityASTM D2571.0E+14ohms
Volume resistivity--ASTM D2571.0E+15ohms·cm
Volume resistivity23°CIEC 600931.0E+15ohms·cm
Dielectric strengthASTM D14927KV/mm
Compared to the anti leakage trace index3.00 mmIEC 60112PLC 3
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessM-ScaleASTM D78595
Rockwell hardnessM -SaleISO 2039-295
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.