PA6 ADDINYL B2 ZV50 ADDIPLAST FRANCE
Properties:
High rigidity good heat aging resistance high heat resistance
Typical Applications:
Parts under the hood of a car applications in the automotive industry
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Parts under the hood of a car | applications in the automotive industry |
| Properties: | High rigidity | good heat aging resistance | high heat resistance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | kJ/m² | 70 | 75 | |
| Charpy Notched Impact Strength | kJ/m² | 13 | 20 | |
| Impact strength of cantilever beam gap | kJ/m² | 20 | 24 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | ,20 | ISO 179/1eA | 13 | KJ/m2 |
| ,75 | ISO 179/1eU | 70 | KJ/m2 | |
| Impact strength of cantilever beam gap | ,24.0 | ISO 180/1A | 20.0 | KJ/m2 |
| Bending modulus | ,7500 | ISO 178 | 14500 | MPa |
| Tensile strain (fracture) | ,3.0 | ISO 527-2 | 2.0 | % |
| Tensile stress (fracture) | ,140 | ISO 527-2 | 220 | MPa |
| Bending modulus | MPa | 14500 | 7500 | |
| Tensile strain | Break | % | 2.0 | 3.0 |
| tensile strength | Break | MPa | 220 | 140 |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | °C | 220 | -- | |
| Hot deformation temperature | 1.8MPa,Unannealed | °C | 215 | -- |
| Linear coefficient of thermal expansion | MD | cm/cm/°C | 2E-05 | -- |
| ,-- | ASTM E831 | 0.000020 | cm/cm/℃ | |
| Melting temperature | ,-DSC法 | ISO 3416 | 220 | ℃ |
| Hot deformation temperature | 1.8 MPa,Unannealed,-HDT | ISO 75-2/Af | 215 | ℃ |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | g/cm³ | 1.55 | -- | |
| Shore hardness | ,78 | ISO 868 | 84 | |
| density | ,-- | ISO 1183/A | 1.55 | g/cm3 |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | SolutionA | V | PLC 1 | |
| Dielectric strength | kV/mm | 35 | 30 | |
| Volume resistivity | ohms·cm | 1E+15 | 1E+11 | |
| Leakage Traceability Index (Solution A) | ,-- | IEC 60112 | 450 | V |
| Volume resistivity | ,1.0E+11 | IEC 60093 | 1E+15 | ohm-cm |
| Dielectric strength | ,30 | IEC 60243-1 | 35 | kv/mm |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | 84 | 78 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.