elastomerTest ConditionTest MethodTest ResultTest Unit
tensile strengthYield2ASTM D41222.8MPa
tensile strengthYield3ASTM D41223.2MPa
tensile strengthYield4ASTM D41223.9MPa
elongationBreak5ASTM D412560%
elongationBreak6ASTM D412540%
elongationBreak7ASTM D412530%
tear strengthASTM D62452.0kN/m
Permanent compression deformation100°C,70hrASTM D39549%
tensile strength300%Strain5ASTM D4129.02MPa
tensile strength300%Strain6ASTM D41210.2MPa
tensile strength300%Strain7ASTM D41210.5MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Heat lossASTM D56880.40%
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
density0.960g/cm³
Mooney viscosityML1+4,100°CASTM D164652MU
bound acrylonitrile contentInternal Method26.0%
stabilizerNon-staining
hardnessTest ConditionTest MethodTest ResultTest Unit
Shore hardnessShoreA2ASTM D224066
Shore hardnessShoreA3ASTM D224067
Shore hardnessShoreA4ASTM D224068
agingTest ConditionTest MethodTest ResultTest Unit
Volume change100°C,70hr,ASTM标准油(3号)ASTM D47138%
Change rate of hardness (Shore) in the airShoreA,100°C,70hrASTM D8654.0
Change rate of tensile strength in air100°C,70hr,在ASTM#1油中ASTM D471-9.0%
Change rate of tensile strength in air100°C,70hr,在ASTM#3油中ASTM D471-30%
Change rate of ultimate elongation in air100°C,70hr,在ASTM#1油中ASTM D471-21%
Change rate of ultimate elongation in air100°C,70hr,在ASTM#3油中ASTM D471-16%
Change rate of hardness (Shore) in the air支撐A,100°C,70hr,在ASTM#1油中ASTM D4710.0
Change rate of hardness (Shore) in the air支撐A,100°C,70hr,在ASTM#3油中ASTM D471-18
Volume change100°C,70hr,ASTM标准油(1号)ASTM D4712.9%
Change rate of tensile strength in air100°C,70hrASTM D865-1.0%
Change rate of ultimate elongation in air100°C,70hrASTM D865-25%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.