| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 2.1 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 19 | kJ/m² |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 2.1 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 19 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB | ||
| UL 94 | HB | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ISO 178 | 4600 | MPa | |
| tensile strength | Break | ISO 527-2/5 | 19.0 | MPa |
| Tensile strain | Break | ISO 527-2/5 | 2.0 | % |
| Bending modulus | ISO 178 | 4600 | MPa | |
| tensile strength | Break | ISO 527-2/5 | 19.0 | MPa |
| Tensile strain | Break | ISO 527-2/5 | 2.0 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 120 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 73.0 | °C | |
| 0.45MPa,Unannealed | ISO 75-2/B | 120 | °C | |
| 1.8MPa,Unannealed | ISO 75-2/A | 73.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 2.00 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 50 | g/10min |
| Shrinkage rate | 2.00mm | Internal Method | 0.40 | % |
| density | ISO 1183 | 2.00 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 50 | g/10min |
| Shrinkage rate | 2.00mm | Internal Method | 0.40 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.