Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.30 g/cm³ |
Shrinkage rate | | ASTMD955 | 0.10 % |
Water absorption rate | | ASTMD570 | 0.40 % |
hardness | Test Condition | Test Method | Test Result |
---|
| Shore A | ASTMD2240 | 90 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTMD4812 | 1400 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 690 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
compressive strength | | ASTMD695 | 15.2 MPa |
Tensile modulus | | ASTMD638 | 607 MPa |
tensile strength | Yield | ASTMD638 | 22.1 MPa |
elongation | Break | ASTMD638 | 10 % |
Flexural modulus | | ASTMD790 | 448 MPa |
bending strength | Yield | ASTMD790 | 21.0 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTMD149 | 16 kV/mm |
dielectric constant | | ASTMD150 | 4.90 |
Dissipation Factor | | ASTMD150 | 0.018 |
Volume resistivity | | ASTMD257 | 1E+11 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 116 °C |
| | ASTMD648 | 54.4 °C |
| | ASTMD696 | 9E-05 cm/cm/°C |
thermal conductivity | | ASTMC177 | 0.36 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.