physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.04 g/cm³ |
Mechanical properties | | ISO 527-2/5 | 2400 MPa |
Tensile stress | | ISO 527-2/5 | 43 MPa |
Tensile strain | | ISO 527-2/5 | 3.0 % |
Impact strength of cantilever beam gap | | ISO 180/1A | 13 kJ/m² |
Thermal performance | | ISO 75-2/B | 97 °C |
Thermal performance | | ISO 306/B | 108 °C |
density | | ISO1183 | 1.04 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | HB |
Burning wire flammability index | | IEC60695-2-12 | 650 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/5 | 2400 MPa |
Tensile stress | | ISO527-2/5 | 43.0 MPa |
Tensile strain | | ISO527-2/5 | 3.0 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO180/1A | 13 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
CTI | | IEC60112 | 400 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Electrical performance | | IEC 60112 | 400 V |
Thermal performance | | 1.60 mm | UL 94 HB |
Thermal performance | | IEC 60695-2-12 | 650 °C |
| | ISO75-2/B | 97.0 °C |
vicat | | ISO306/B | 108 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.