ABS 25H30000 4Plas
Properties:
Characteristic high liquidity
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Characteristic | high liquidity |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 13 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 650 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break,23°C | ISO 527-2/5 | 3.0 | % |
| tensile strength | Break,23°C | ISO 527-2/5 | 43.0 | MPa |
| Tensile modulus | 23°C | ISO 527-2/5 | 2400 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ISO 306/B | 108 | °C | |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 97.0 | °C |
| Thermal Properties | 热灯丝点火温度,2.00 mm | IEC 60695-2-12 | 650 | °C |
| 其他,UL 阻燃等级 | UL 94 | HB | 1.60 mm | |
| Electrical Properties | 漏电起痕指数 | IEC 60112 | 400 | V |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.04 | g/cm³ | |
| Thermal Properties | 维卡软化温度 | ISO 306/B | 108 | °C |
| 热变形温度,0.45 MPa, Unannealed | ISO 75-2/B | 97 | °C | |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 13 | kJ/m² |
| Tensile strain | Break, 23°C | ISO 527-2/5 | 3.0 | % |
| tensile strength | Break, 23°C | ISO 527-2/5 | 43 | MPa |
| Tensile modulus, 23 ° C | ISO 527-2/5 | 2400 | MPa | |
| density | ISO 1183 | 1.04 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.