PP BX3500 SK KOREA
52
Form:Granules | Grade:Impact resistant grade
Properties:
High impact resistanceHigh rigidityheat-resistingHigh mobilityHigh crystallinity
Typical Applications:
Thin walled componentsIndustrial applicationsBattery boxHome appliance componentscontainerElectronic fieldElectrical fieldAutomotive sector
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Thin walled components | Industrial applications | Battery box | Home appliance components | container | Electronic field | Electrical field | Automotive sector |
| Properties: | High impact resistance | High rigidity | heat-resisting | High mobility | High crystallinity |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 98 | J/m |
| -20°C | ASTM D256 | 59 | J/m | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ASTM D790 | 1670 | Mpa | |
| elongation | Break | ASTM D638 | 300 | % |
| tensile strength | Yield | ASTM D638 | 32.4 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | HDT | ASTM D648 | 135 | °C |
| Vicat softening temperature | ASTM D1525 | 155 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Spiral flow length | Internal Method | 80.0 | CM | |
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 10 | g/10min |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 100 | |
| aging | Test Condition | Test Method | Test Result | Test Unit |
| Oven aging | ASTM D3012 | 15.0 | day |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.