PA66 70G35HSL NC DUPONT USA
95
Form:Granules | Grade:Enhanced level
Properties:
Thermal stabilityFiller: Glass fiber reinf35%Filler by weight35%Filler by weight
Typical Applications:
sporting goodsElectrical applications
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | sporting goods | Electrical applications |
| Properties: | Thermal stability | Filler: Glass fiber reinf | 35% | Filler by weight | 35% | Filler by weight |
Certificates

Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| tensile strength | 23°C | ISO 527-2 | 210 | Mpa |
| Elongation at Break | 23°C | ISO 527-2 | 3.20 | % |
| Tensile modulus | 23°C | ISO 527-2 | 11200 | Mpa |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 15 | kJ/m² |
| -30°C | ISO 179/1eA | 10 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 90 | kJ/m² |
| -30°C | ISO 179/1eU | 80 | kJ/m² | |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 12 | kJ/m² |
| -30°C | ISO 180/1A | 10 | kJ/m² | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | Melting Temperature | ISO 11357-3 | 262 | °C |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 2E-05 | cm/cm/°C |
| TD | ISO 11359-2 | 1E-04 | cm/cm/°C | |
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 261 | °C |
| 1.80MPaAnnealed | ISO 75-2/Af | 252 | °C | |
| Vicat softening temperature | ISO 306/B50 | 255 | °C | |
| 玻璃转化温度 | ISO 11357-2 | 80 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.41 | g/cm³ | |
| Shrinkage rate | MD2.0mm | ISO 294-4 | 0.30 | % |
| TD2.0mm | ISO 294-4 | 1.10 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+13 | Ω.cm | |
| Dielectric strength | IEC 60243-1 | 33 | KV/mm | |
| Dissipation factor | 相对漏电起痕指数 | IEC 60112 | 400 | V |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | ISO 2039-2 | 105 | M(Scale) | |
| ISO 2039-2 | 125 | R | ||
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 0.71mm | |
| UL -94 | HB | 1.50mm | ||
| UL -94 | HB | 3.00mm | ||
| Extreme Oxygen Index | ISO 4589-2 | 24 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.