Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
water content | | | 0.010 % |
Shrinkage rate | | ASTM D955 | 0.15to0.40 % |
density | | ASTM D792 | 1.64 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Primary Additive | | | 30 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D790 | 234 MPa |
Flexural modulus | | ASTM D790 | 10300 MPa |
elongation | Yield | ASTM D638 | 2.0to3.0 % |
tensile strength | | ASTM D638 | 159 MPa |
Tensile modulus | | ASTM D638 | 10700 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 120 J/m |
Suspended wall beam without notch impact strength | | ASTM D4812 | 770 J/m |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | >316 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.