Share
Add to compare

PA66 A3 V2 NC 1102 CELANESE GERMANY

22

Form:Granules

Product Description
Certificates(0)
Datasheet

Product Description

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch-30°CISO 179/1eUNoBreak
Impact strength of simply supported beam without notch23°CISO 179/1eUNoBreak
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.40mmUL 94V-2
UL flame retardant rating0.8mmUL 94V-2
UL flame retardant rating1.6mmUL 94V-2
UL flame retardant rating3.2mmUL 94V-2
Burning wire flammability index0.8mmIEC 60695-2-12960°C
Burning wire flammability index3.2mmIEC 60695-2-12960°C
Extreme Oxygen IndexISO 4589-229%
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulus23°CISO 527-23150Mpa
tensile strengthYield,23°CISO 527-280.0Mpa
Tensile strainBreak,23°CISO 527-210%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B200°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A85.0°C
Continuous use temperatureIEC 60216125°C
Ball Pressure Test125°CIEC 60695-10-2Pass
Ball Pressure Test165°CIEC 60695-10-2Pass
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateTD:23°CISO 294-42.1%
Shrinkage rateMD:23°CISO 294-41.8%
Water absorption rate23°C,24hrISO 622.2%
Water absorption rateSaturation,23°CISO 628.0%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace index3.20mm,SolutionAIEC 60112PLC 0
Needle flame test1.00mmIEC 60695-11-5Pass
Needle flame test2.00mmIEC 60695-11-5Pass
Surface resistivityIEC 600931E+13ohms
Volume resistivity23°CIEC 600931E+15ohms·cm
Dielectric strength2.00mmIEC 60243-124KV/mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.