| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | NoBreak | |
| 23°C | ISO 179/1eU | NoBreak | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.40mm | UL 94 | V-2 | |
| 0.8mm | UL 94 | V-2 | ||
| 1.6mm | UL 94 | V-2 | ||
| 3.2mm | UL 94 | V-2 | ||
| Burning wire flammability index | 0.8mm | IEC 60695-2-12 | 960 | °C |
| 3.2mm | IEC 60695-2-12 | 960 | °C | |
| Extreme Oxygen Index | ISO 4589-2 | 29 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2 | 3150 | Mpa |
| tensile strength | Yield,23°C | ISO 527-2 | 80.0 | Mpa |
| Tensile strain | Break,23°C | ISO 527-2 | 10 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 200 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 85.0 | °C | |
| Continuous use temperature | IEC 60216 | 125 | °C | |
| Ball Pressure Test | 125°C | IEC 60695-10-2 | Pass | |
| 165°C | IEC 60695-10-2 | Pass | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD:23°C | ISO 294-4 | 2.1 | % |
| MD:23°C | ISO 294-4 | 1.8 | % | |
| Water absorption rate | 23°C,24hr | ISO 62 | 2.2 | % |
| Saturation,23°C | ISO 62 | 8.0 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | 3.20mm,SolutionA | IEC 60112 | PLC 0 | |
| Needle flame test | 1.00mm | IEC 60695-11-5 | Pass | |
| 2.00mm | IEC 60695-11-5 | Pass | ||
| Surface resistivity | IEC 60093 | 1E+13 | ohms | |
| Volume resistivity | 23°C | IEC 60093 | 1E+15 | ohms·cm |
| Dielectric strength | 2.00mm | IEC 60243-1 | 24 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.