TP, Unspecified Mecoline IS RDX 1218 F MELOS GERMANY
0
- Usages:Cable sheath ship applications aerospace applications wire and cable applications insulation materials
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| toxicity | EN50305 | 2.00 | |
| VerticalBurnTest | <540 mm | ||
| HalogenContent | IEC 754-1 | 0 % | |
| Extreme Oxygen Index | ASTM D2863 | 40 % |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile strain | Break,-40°C | IEC 811-1-4 | >35 % |
| Break3 | IEC 811-1-1 | >180 % | |
| Break2 | IEC 811-1-1 | >200 % | |
| tensile strength | --3 | IEC 811-1-1 | >12.0 MPa |
| --2 | IEC 811-1-1 | >9.00 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| thermosetting | Elongationunderload | IEC 540 | <40 % |
| Temperature index | ASTM D2863 | 300 °C | |
| Hot pressing test | 穿透 | DIN VDE0472 | <50 % |
| thermosetting | Residualelongation | IEC 540 | <10 % |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | IEC 811-1-3 | <2.0 % | |
| PH value | IEC 60754-2 | >4.5 | |
| melt mass-flow rate | 175°C/21.6kg | ISO 1133 | 7.0 g/10min |
| density | ISO 1183/A | 1.62 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| conductivity | <4.00 µS/mm | ||
| Volume resistivity | 23°C | IEC 60093 | >1.0E+10 ohms·cm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shore hardness | ShoreA | ISO 7619 | 85 |
| aging | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile stress change rate | 120°C,240hr,Break | IEC 811-1-2 | <25 % |
| Change rate of tensile strength in air | 120°C,240hr | IEC 811-1-2 | <25 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.